Abstract: The paper presents the data that allow calculate the attenuation factors in lead, tungsten and concrete of various thicknesses or the thickness of shielding made of these materials for a given attenuation factor for the spectra of gamma radiation of 131I and 177Lu radionuclides. Using these data the effectiveness of the protection of supporting equipment (portable containers, shielded syringes, etc.) and the possible doses of external radiation of medical personnel in the radionuclide therapy department were calculated. It is shown that there a...